Baseline-systems BHM Series Hydrometer Instrukcja Użytkownika Strona 29

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 28
Hydrometers Operation and Maintenance Manual29
Maintenance 3” and 4” Models
HYDROMETER DIS-ASSEMBLY AND RE-
ASSEMBLY
Dis-assembly of the 3and 4hydrometer is divided into the following
assemblies:
Cover Assembly
Diaphragm/Stem and Base Assemblies
Inlet Spider/Strainer Assembly
Perform only those steps necessary to inspect and replace parts as directed
by the troubleshooting procedures. It is recommended to replace the
various
o-rings and gaskets during dis-assembly as well as to inspect certain
other parts. All gaskets and o-rings must be covered with grease prior to
installation.
HYDROMETER COVER AND BASE SUB-
ASSEMBLIES
Removal
Remove the register subassembly as described on page 24.
Loosen and remove the cover screws (10) along with the washers.
Lift the cover off of the hydrometer body (29). Be especially careful
not to damage the impeller.
Carefully remove the impeller assembly (37) from the hydrometer
body.
Inspect the impeller and its components for signs of excessive wear
or damage. Verify that the impeller shaft is straight. Replace as
necessary.
Inspect the base o-ring (42) for excessive wear or damage. Replace as
necessary.
Re-assembly
Insert the impeller (37) into the inlet spider (located inside the
hydrometer base).
Insert the base “O” ring (42) into the groove on the upper body ange.
Carefully place the cover over the impeller shaft (37) and onto the
hydrometer body (29).
Replace and tighten the cover screws (10).
Replace the register subassembly as described on page 24.
Przeglądanie stron 28
1 2 ... 24 25 26 27 28 29 30 31 32 33 34 ... 51 52

Komentarze do niniejszej Instrukcji

Brak uwag